NavienManager

HomeKit and diagnostics for Navien NPE-240A (though may work with others) using ESP32 + RS485

Why

While the Navien Tankless Hot Water unit supports Wi-Fi via NaviLink, there are two important features it lacks:

  1. Vacation Mode
    A way to automate vacation mode — either through a schedule with a defined start and end time, or by integrating with a system like HomeKit — is essential to me. Vacation mode prevents wasting gas on unnecessary recirculation. While I could manually turn the unit off before leaving and back on upon returning, automation allows me to “set it and forget it,” which is far more convenient and reliable.
  2. Hot Water Now + Recirculation Schedule
    With NaviLink, I can configure a fixed schedule for recirculation. However, this does not work with Navien’s “Hot Button.” You can have one or the other — not both. I wanted a way to trigger recirculation for a fixed period outside of the scheduled times. This allows me to avoid wasting water while waiting for it to get hot.

Description

My home is a HomeKit home, and I wanted to control the hot water unit through it. I decided to model the hot water unit as a thermostat. This allows me to say things like “Hey Siri, turn on Hot Water Heater” or create any number of scenes that activate recirculation. I’ve enabled two modes of operation:

Monitor Mode

In this mode, a NaviLink Wi-Fi box is attached and controls the Navien tankless hot water unit. Adjusting any HomeKit settings in this mode has no effect; they will simply revert to reflect the current state of the unit.

  • If the HomeKit thermostat shows HEAT, it means recirculation is currently running, or that a tap is open and the unit is actively heating water. The setpoint reflects the unit’s configured temperature.
  • If the thermostat shows OFF, the system is idle, and the setpoint is set to the minimum value. The adjustment of the setpoint is useful to show in the Eve app when the hot water unit is heating or not.

Control Mode (WIP - still validating)

The NaviLink box is not attached, allowing full control via HomeKit. In this mode, a schedule can be defined using the Eve app. The setpoint should be controlled via Apple’s Home app, as Eve does not support the full temperature range of a hot water unit. The temperature set in the Home app overrides any setpoint from the Eve schedule.

The thermostat states represent the same as Monitor mode. However, changing them now has an effect.

  • Switching to HEAT activates recirculation for 5 minutes, after which it returns to the schedule. If it is already running, it has no effect.
  • Switching to OFF turns off recirculation if it was running. The thermostat will return to schedule when the next scheduled event occurs.
  • If Vacation Mode is enabled via Automation in the Eve app, the hot water unit will be powered off and all schedules will be suspended.

Features

The NavienManager has a number of features that came about as due process when working on a solution. I initially wanted to log the behaviour of the unit, which caused me to create a data broadcast component. Then I wanted to investigate the data that it was sending, which caused me to add Telnet support. Then as I was building out the HomeKit integration, I found that it didn't present all the information I wanted to see, so I built out a web interface. The core functionality for the RS-485 interface was built out by a team of people on Home Assist, with the foundation of the Navien C++ class by htumanyan

HomeKit Integration and Eve App

The HomeKit integration is described in the Description section above, but there are a few additional points worth noting:

  • You may see the setpoint fluctuate on the temperature graph. This is intentional and indicates when the unit is actively heating to the setpoint versus when it is idle. The lower setpoint represents the minimum temperature that the hot water unit can be set to.
  • The Valve graph shows the current operating load. When the valve is open, the unit is actively heating, and the graph reflects its current operating capacity.
  • The Valve metric is not shown by default in the Eve app. To enable it, edit the Thermostat page and manually add it as a visible characteristic.
    Eve thermostat screen

Web Server (via HomeSpan)

The current status of the Navien unit can be viewed at any time by visiting its web page. The webpage is hosted at the IP address of the ESP32, e.g., http://<ip-address>/status.

At the top of the status page is a green toggle button. Tapping it switches the units displayed on the screen between metric and imperial.

There are two schedulers shown:

  1. The built-in Navien scheduler, which does not support "Hot Water Now" functionality.
  2. A custom scheduler provided by this project, which does support "Hot Water Now" requests even while a schedule is running.

If both schedulers are active, the Navien scheduler takes precedence. In the image below, shows the system running in Monitor mode. Attempts to change the state of the hotwater unit are correctly failing.

Navien Status screen

Telnet

Because the hot water unit is not in a convenient location for active development, I added Telnet capabilities to the ESP32. This allows a user to investigate and control the hot water unit remotely, as well as monitor its activity in real time. The Telnet functionality is broken into several categories:

General operation commands:

  • bye — Disconnect
  • wifi — Print WiFi status
  • fsStat — Show file system status
  • reboot — Reboot the ESP32
  • ping — Test if Telnet commands are working

History and program state:

  • eraseHistory — Erase all history entries
  • erasePgm — Erase all program state
  • history — Print history entries in CSV format (optional: specify number of entries)

Navien hot water monitoring:

  • gas — Print current gas state as JSON
  • water — Print current water state as JSON
  • trace — Dump interactions (options: gas, water, command, announce)
  • stop — Stop tracing

Navien control commands:

  • control — Check if control commands are available
  • hotButton — Send Hot Button command
  • power — Set or get power state (on/off)
  • recirc — Set or get recirculation state (on/off)
  • setTemp — Set or get temperature setpoint

Time operations:

  • time — Print local and GMT time
  • timezone — Set or get the current timezone

Data broadcast (UDP)

To continuously monitor and log the status of the Navien unit, the software broadcasts its status over the local network (not the internet) using UDP on port 2025. Duplicate data is throttled to one broadcast every 5 seconds—if the same packet is observed again within that time, it is dropped. However, if the packet changes in any way, it will be broadcast immediately.
This broadcasted data can be collected on another machine and used for logging. In the Logging folder, there is an example script that collects the broadcast data and logs it to InfluxDB. A Grafana template is also provided, which can be used in conjunction with InfluxDB to visualize the collected data.
Grafana status

Setup

Hardware

This project requires an ESP32 and an RS-485 to serial interface. Below are the components I personally used, along with why I chose them.

I chose the ESP32 D1 Mini because I’ve used WeMos mini boards before, have a number of shields for them, and find them easy to develop for using the Arduino SDK.

For the RS-485 interface, I found a WeMos-compatible RS-485 shield that works perfectly with the D1 Mini. It not only provides the required RS-485 connection, but also includes a DC-DC converter that can draw power from the Navien system.
(Note: I’m not yet using this feature, as my Navien unit does not provide power on the NaviLink cable.)

To tap into the communication line, I used a breakout box. My Navien unit already had a NaviLink module installed, so I wanted to begin by passively monitoring the traffic between the NaviLink and the Navien unit. Placing the breakout box inline allowed me to do just that. The middle two lines on the breakout box are the two lines I connected to the RS-485 sheild. In the photo below, the Blue wire is attached to the B- terminal of the RS-485 shield, and the Purple wire is attached to the A+ terminal.

RJ45 breakout box

🧩 Parts List

Component Description Link
ESP32 D1 Mini Compact ESP32 Dev Board AliExpress
RS-485 CANBUS DCDC Shield RS-485 & Power Shield for D1 Mini Taaralabs
RJ45 Ethernet Breakout Box RJ45 Tap for intercepting NaviLink connection Amazon

Software

The code is broken up logically by functionality.

  1. NavienManager - Main startup file.
  2. Navien - Handles communication to the Navien Hot Water unit
  3. HomeSpanWeb - Contains all the web functions for HomeSpan to present a pretty web page
  4. DEV_Navien - HomeKit Themostat Service implementation
  5. FakeGatoScheduler - Handles the Eve specific Program Data, built on top of SchedulerBase, used in conjection with DEV_Navien
  6. SchedulerBase - generic baseclass to implement a day-of-week scheduler.
  7. FakeGatoHistoryService - HomeKit FakeGatoHistory Service implementation
  8. NavienBroadcaster - Receives callbacks from Navien of state changes and broadcasts over UDP
  9. TelnetCommands - Implements all the telnet commands.
  10. Logging - Folder contains the scripts listen for Navien broadcasts and write them to InfluxDB as well as Grafana templates

License

This library is licensed under MIT License

Acknowledgements

Community members of Home Assist, who decoded the protocol and much of the packet data for the Navien NaviLink connection
htumanya for the well-crafted base class for Navien
simont77 for decoding the Eve History logging interface
HomeSpan for the HomeKit accessory library for ESP32 devices

About

HomeKit and diagnostics for Navien Tankless Water Heater using ESP32 + RS485